mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-06-08 22:18:26 +00:00
- Added submission from ICS-CERT for ICSA-17-047-02 from 2018-04-10.
This commit is contained in:
parent
8a61eec6bb
commit
e8bbf97ff7
@ -1,8 +1,32 @@
|
||||
{
|
||||
"CVE_data_meta" : {
|
||||
"ASSIGNER" : "cve@mitre.org",
|
||||
"ASSIGNER" : "ics-cert@hq.dhs.gov",
|
||||
"DATE_PUBLIC" : "2017-03-21T00:00:00",
|
||||
"ID" : "CVE-2017-6015",
|
||||
"STATE" : "RESERVED"
|
||||
"STATE" : "PUBLIC"
|
||||
},
|
||||
"affects" : {
|
||||
"vendor" : {
|
||||
"vendor_data" : [
|
||||
{
|
||||
"product" : {
|
||||
"product_data" : [
|
||||
{
|
||||
"product_name" : "FactoryTalk Activation",
|
||||
"version" : {
|
||||
"version_data" : [
|
||||
{
|
||||
"version_value" : "FactoryTalk Activation Service, Version 4.00.02 and prior versions."
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name" : "Rockwell Automation"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format" : "MITRE",
|
||||
"data_type" : "CVE",
|
||||
@ -11,7 +35,26 @@
|
||||
"description_data" : [
|
||||
{
|
||||
"lang" : "eng",
|
||||
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value" : "Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later. Rockwell Automation reported the vulnerability."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype" : {
|
||||
"problemtype_data" : [
|
||||
{
|
||||
"description" : [
|
||||
{
|
||||
"lang" : "eng",
|
||||
"value" : "Unquoted search path or element CWE-428"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references" : {
|
||||
"reference_data" : [
|
||||
{
|
||||
"url" : "https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
Loading…