- Synchronized data.

This commit is contained in:
CVE Team 2018-06-18 15:04:04 -04:00
parent b0357d47c5
commit eb48c240fd
No known key found for this signature in database
GPG Key ID: 0DA1F9F56BC892E8
3 changed files with 9 additions and 3 deletions

View File

@ -35,7 +35,7 @@
"description_data" : [
{
"lang" : "eng",
"value" : "The application utilizes a fixed-length heap buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash."
"value" : "Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length heap buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash."
}
]
},
@ -54,6 +54,8 @@
"references" : {
"reference_data" : [
{
"name" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-01",
"refsource" : "MISC",
"url" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-01"
}
]

View File

@ -35,7 +35,7 @@
"description_data" : [
{
"lang" : "eng",
"value" : "The application utilizes a fixed-length stack buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash."
"value" : "Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length stack buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash."
}
]
},
@ -54,6 +54,8 @@
"references" : {
"reference_data" : [
{
"name" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-01",
"refsource" : "MISC",
"url" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-01"
}
]

View File

@ -35,7 +35,7 @@
"description_data" : [
{
"lang" : "eng",
"value" : "The application performs read operations on a memory buffer where the position can be determined by a value read from a .dpa file. This may cause improper restriction of operations within the bounds of the memory buffer, allow remote code execution, alter the intended control flow, allow reading of sensitive information, or cause the application to crash."
"value" : "Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior performs read operations on a memory buffer where the position can be determined by a value read from a .dpa file. This may cause improper restriction of operations within the bounds of the memory buffer, allow remote code execution, alter the intended control flow, allow reading of sensitive information, or cause the application to crash."
}
]
},
@ -54,6 +54,8 @@
"references" : {
"reference_data" : [
{
"name" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-01",
"refsource" : "MISC",
"url" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-01"
}
]