"-Synchronized-Data."

This commit is contained in:
CVE Team 2023-11-15 04:00:34 +00:00
parent f726459659
commit f55b50808f
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
5 changed files with 463 additions and 20 deletions

View File

@ -1,17 +1,98 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-5984",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "\nA CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow\nmodified firmware to be uploaded when an authorized admin user begins a firmware update\nprocedure.\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-494 Download of Code Without Integrity Check",
"cweId": "CWE-494"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Schneider Electric",
"product": {
"product_data": [
{
"product_name": "ION8650",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "ION8800 ",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-01.pdf",
"refsource": "MISC",
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-01.pdf"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,98 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-5985",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "\n\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\nexists that could cause compromise of a user\u2019s browser when an attacker with admin privileges\nhas modified system values.\n\n\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
"cweId": "CWE-79"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Schneider Electric",
"product": {
"product_data": [
{
"product_name": "ION8650",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "ION8800 ",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-01.pdf",
"refsource": "MISC",
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-01.pdf"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,117 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-5986",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-601 URL Redirection to Untrusted Site ('Open Redirect')",
"cweId": "CWE-601"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Schneider Electric",
"product": {
"product_data": [
{
"product_name": "EcoStruxure Power Monitoring Expert (PME)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Version 2020 CU2 and prior"
},
{
"version_affected": "=",
"version_value": "Version 2021 CU1 and prior"
}
]
}
},
{
"product_name": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"
},
{
"version_affected": "=",
"version_value": "Advanced Reporting and Dashboards Module 2020 prior to CU3"
}
]
}
},
{
"product_name": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf",
"refsource": "MISC",
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,117 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-5987",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
"cweId": "CWE-79"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Schneider Electric",
"product": {
"product_data": [
{
"product_name": "EcoStruxure Power Monitoring Expert (PME)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Version 2020 CU2 and prior"
},
{
"version_affected": "=",
"version_value": "Version 2021 CU1 and prior"
}
]
}
},
{
"product_name": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021"
},
{
"version_affected": "=",
"version_value": "Advanced Reporting and Dashboards Module 2020 prior to CU3"
}
]
}
},
{
"product_name": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf",
"refsource": "MISC",
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,98 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-6032",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')\nvulnerability exists that could cause a file system enumeration and file download when an\nattacker navigates to the Network Management Card via HTTPS.\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
"cweId": "CWE-22"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Schneider Electric",
"product": {
"product_data": [
{
"product_name": "Galaxy VS",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "v6.82"
}
]
}
},
{
"product_name": "Galaxy VL",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "v12.21"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-03.pdf",
"refsource": "MISC",
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-03.pdf"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
]
}