{ "data_type": "CVE", "data_format": "MITRE", "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2021-23848", "ASSIGNER": "psirt@bosch.com", "DATE_PUBLIC": "2021-05-20", "TITLE": "Reflected XSS in URL handler", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Bosch", "product": { "product_data": [ { "product_name": "CPP Firmware", "version": { "version_data": [ { "version_value": "all", "version_affected": "=", "platform": "CPP4, CPP6, CPP7, CPP7.3, CPP13" } ] } } ] } } ] } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" } ] } ] }, "impact": { "cvss": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "HIGH", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH" } }, "references": { "reference_data": [ { "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html", "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html", "refsource": "CONFIRM" } ] }, "description": { "description_data": [ { "lang": "eng", "value": "An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context of the user." } ] }, "source": { "discovery": "UNKNOWN" } }