{ "CVE_data_meta" : { "ASSIGNER" : "cve@mitre.org", "ID" : "CVE-2018-7268", "STATE" : "PUBLIC" }, "affects" : { "vendor" : { "vendor_data" : [ { "product" : { "product_data" : [ { "product_name" : "n/a", "version" : { "version_data" : [ { "version_value" : "n/a" } ] } } ] }, "vendor_name" : "n/a" } ] } }, "data_format" : "MITRE", "data_type" : "CVE", "data_version" : "4.0", "description" : { "description_data" : [ { "lang" : "eng", "value" : "MagniComp SysInfo before 10-H81, as shipped with BMC BladeLogic Automation and other products, contains an information exposure vulnerability in which a local unprivileged user is able to read any root (uid 0) owned file on the system, regardless of the file permissions. Confidential information such as password hashes (/etc/shadow) or other secrets (such as log files or private keys) can be leaked to the attacker. The vulnerability has a confidentiality impact, but has no direct impact on system integrity or availability." } ] }, "problemtype" : { "problemtype_data" : [ { "description" : [ { "lang" : "eng", "value" : "n/a" } ] } ] }, "references" : { "reference_data" : [ { "name" : "20180518 MagniComp SysInfo Information Exposure [CVE-2018-7268]", "refsource" : "BUGTRAQ", "url" : "http://www.securityfocus.com/archive/1/542024/100/0/threaded" }, { "name" : "http://packetstormsecurity.com/files/147687/MagniComp-SysInfo-Information-Exposure.html", "refsource" : "MISC", "url" : "http://packetstormsecurity.com/files/147687/MagniComp-SysInfo-Information-Exposure.html" }, { "name" : "https://sintonen.fi/advisories/magnicomp-sysinfo-information-exposure.txt", "refsource" : "MISC", "url" : "https://sintonen.fi/advisories/magnicomp-sysinfo-information-exposure.txt" } ] } }