{ "data_type": "CVE", "data_format": "MITRE", "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2021-20595", "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "n/a", "product": { "product_data": [ { "product_name": "Air Conditioning System/Centralized Controllers G-50A; GB-50A; GB-24A; AG-150A-A; AG-150A-J; GB-50ADA-A; GB-50ADA-J; EB-50GU-A; EB-50GU-J; AE-200A; AE-200E; AE-50A; AE-50E; EW-50A; EW-50E; TE-200A; TE-50A; TW-50A; CMS-RMD-J; Air Conditioning System/Expansion Controllers PAC-YG50ECA; Air Conditioning System/BM adapter BAC-HD150", "version": { "version_data": [ { "version_value": "Ver.3.35 and prior" }, { "version_value": "Ver.3.35 and prior" }, { "version_value": "Ver.9.11 and prior" }, { "version_value": "Ver.3.20 and prior" }, { "version_value": "Ver.3.20 and prior" }, { "version_value": "Ver.3.20 and prior" }, { "version_value": "Ver.3.20 and prior" }, { "version_value": "Ver 7.09 and prior" }, { "version_value": "Ver 7.09 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver 7.93 and prior" }, { "version_value": "Ver.1.30 and prior" }, { "version_value": "Ver.2.20 and prior" }, { "version_value": "Ver.2.21 and prior" } ] } } ] } } ] } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Improper Restriction of XML External Entity Reference" } ] } ] }, "references": { "reference_data": [ { "refsource": "MISC", "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-005_en.pdf", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-005_en.pdf" }, { "refsource": "MISC", "name": "https://jvn.jp/vu/JVNVU93086468/index.html", "url": "https://jvn.jp/vu/JVNVU93086468/index.html" } ] }, "description": { "description_data": [ { "lang": "eng", "value": "Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets." } ] } }