{ "data_type": "CVE", "data_format": "MITRE", "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2020-7478", "ASSIGNER": "cybersecurity@schneider-electric.com", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "n/a", "product": { "product_data": [ { "product_name": "IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)", "version": { "version_data": [ { "version_value": "IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)" } ] } } ] } } ] } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory" } ] } ] }, "references": { "reference_data": [ { "refsource": "MISC", "name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/", "url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/" }, { "refsource": "MISC", "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-371/", "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-371/" } ] }, "description": { "description_data": [ { "lang": "eng", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled." } ] } }