{ "data_type": "CVE", "data_format": "MITRE", "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2021-21826", "ASSIGNER": "talos-cna@cisco.com", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "n/a", "product": { "product_data": [ { "product_name": "AT&T", "version": { "version_data": [ { "version_value": "AT&T Labs Xmill 0.7, Schneider Electric EcoStruxure Control Expert 15" } ] } } ] } } ] } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')" } ] } ] }, "references": { "reference_data": [ { "refsource": "MISC", "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1291", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1291" } ] }, "description": { "description_data": [ { "lang": "eng", "value": "A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT&T Labs Xmill 0.7. Within `DecodeTreeBlock` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer. An attacker can provide a malicious file to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 8.1, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } }