{ "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2021-09-27T15:34:00.000Z", "ID": "CVE-2021-38450", "STATE": "PUBLIC", "TITLE": "Trane Tracer Code Injection" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Tracer SC", "version": { "version_data": [ { "version_affected": "<", "version_name": "All", "version_value": "4.4 SP7" } ] } }, { "product_name": "Tracer SC+", "version": { "version_data": [ { "version_affected": "<", "version_name": "All", "version_value": "5.5 SP3" } ] } }, { "product_name": "Tracer Concierge", "version": { "version_data": [ { "version_affected": "<", "version_name": "All", "version_value": "5.5 SP3" } ] } } ] }, "vendor_name": "Trane" } ] } }, "credit": [ { "lang": "eng", "value": "Trane reported this vulnerability to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The affected controllers do not properly sanitize the input containing code syntax. As a result, an attacker could craft code to alter the intended controller flow of the software." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-94 Improper Control of Generation of Code ('Code Injection')" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-266-02", "refsource": "CONFIRM", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-266-02" } ] }, "solution": [ { "lang": "eng", "value": "Affected users should contact a Trane representative to install updated firmware or request additional information. Please reference Trane service database number HUB-205962 when contacting the Trane office.\n\nTracer SC is no longer actively developed, tested, or sold. Tracer SC will be considered end-of-life on December 31, 2022. Trane recommends identifying a migration plan for replacing the Tracer SC controller with the next-generation Tracer SC+ controller. Tracer SC+ can function as a drop-in replacement for Tracer SC, providing significant updates to security capabilities.\n\nTrane has identified the following specific mitigations:\n\nTracer SC: Upgrade to v4.4 SP7 or later\nTracer SC+: Upgrade to v5.5 SP3 or later\nTracer Concierge: Upgrade to v5.5 SP3 or later" } ], "source": { "advisory": "https://us-cert.cisa.gov/ics/advisories/icsa-21-266-02", "discovery": "UNKNOWN" } }