{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2024-47944", "ASSIGNER": "security-research@sec-consult.com", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "The device directly executes .patch firmware upgrade files on a USB stick without any prior authentication in the admin interface. This leads to an unauthenticated code execution via the\u00a0firmware upgrade function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-1299: Missing Protection Mechanism for Alternate Hardware Interface", "cweId": "CWE-1299" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "RITTAL GmbH & Co. KG", "product": { "product_data": [ { "product_name": "IoT Interface & CMC III Processing Unit", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "versions": [ { "status": "affected", "version": "<6.21.00.2", "versionType": "custom" } ], "defaultStatus": "affected" } } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://r.sec-consult.com/rittaliot", "refsource": "MISC", "name": "https://r.sec-consult.com/rittaliot" }, { "url": "https://www.rittal.com/de-de/products/deep/3124300", "refsource": "MISC", "name": "https://www.rittal.com/de-de/products/deep/3124300" } ] }, "generator": { "engine": "Vulnogram 0.2.0" }, "source": { "discovery": "UNKNOWN" }, "exploit": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "SEC Consult has published proof of concept code for this vulnerability." } ], "value": "SEC Consult has published proof of concept code for this vulnerability." } ], "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
The vendor provides a patched version V6.21.00.2 which can be downloaded from the following URL: www.rittal.com/de-de/products/deep/3124300