{ "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13926", "STATE": "PUBLIC" }, "data_format": "MITRE", "data_version": "4.0", "data_type": "CVE", "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Siemens", "product": { "product_data": [ { "product_name": "SCALANCE S602", "version": { "version_data": [ { "version_value": "All versions >= V3.0 and < V4.1" } ] } }, { "product_name": "SCALANCE S612", "version": { "version_data": [ { "version_value": "All versions >= V3.0 and < V4.1" } ] } }, { "product_name": "SCALANCE S623", "version": { "version_data": [ { "version_value": "All versions >= V3.0 and < V4.1" } ] } }, { "product_name": "SCALANCE S627-2M", "version": { "version_data": [ { "version_value": "All versions >= V3.0 and < V4.1" } ] } } ] } } ] } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device." } ] }, "references": { "reference_data": [ { "refsource": "CONFIRM", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "refsource": "MISC", "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ] } }