{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2023-1899", "ASSIGNER": "ics-cert@hq.dhs.gov", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "Atlas Copco Power Focus 6000 web server is not a secure connection by default, which could allow an attacker to gain sensitive information by monitoring network traffic between user and controller." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-319 Cleartext Transmission of Sensitive Information" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Atlas Copco", "product": { "product_data": [ { "product_name": "Power Focus", "version": { "version_data": [ { "version_affected": "=", "version_value": "6000" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-159-01", "refsource": "MISC", "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-159-01" } ] }, "generator": { "engine": "VINCE 2.1.2", "env": "prod", "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-1899" }, "source": { "discovery": "UNKNOWN" }, "impact": { "cvss": [ { "version": "3.1", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "availabilityImpact": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H", "baseScore": 9.4, "baseSeverity": "CRITICAL" } ] } }