{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2023-2265", "ASSIGNER": "security@selinc.com", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "An\u00a0Improper Restriction of Rendered UI Layers or Frames in the Schweitzer Engineering Laboratories SEL-411L could allow an unauthenticated attacker to perform clickjacking based attacks against an authenticated and authorized user.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-1021 Improper Restriction of Rendered UI Layers or Frames", "cweId": "CWE-1021" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Schweitzer Engineering Laboratories", "product": { "product_data": [ { "product_name": "SEL-411L", "version": { "version_data": [ { "version_affected": "<", "version_name": "R118-V0", "version_value": "R118-V4" }, { "version_affected": "<", "version_name": "R119-V0", "version_value": "R119-V5" }, { "version_affected": "<", "version_name": "R120-V0", "version_value": "R120-V6" }, { "version_affected": "<", "version_name": "R121-V0", "version_value": "R121-V3" }, { "version_affected": "<", "version_name": "R122-V0", "version_value": "R122-V3" }, { "version_affected": "<", "version_name": "R123-V0", "version_value": "R123-V3" }, { "version_affected": "<", "version_name": "R124-V0", "version_value": "R124-V3" }, { "version_affected": "<", "version_name": "R125-V0", "version_value": "R125-V3" }, { "version_affected": "<", "version_name": "R126-V0", "version_value": "R126-V4" }, { "version_affected": "<", "version_name": "R127-V0", "version_value": "R127-V2" }, { "version_affected": "<", "version_name": "R128-V0", "version_value": "R128-V1" }, { "version_affected": "<", "version_name": "R129-V0", "version_value": "R129-V1" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://selinc.com/support/security-notifications/external-reports/", "refsource": "MISC", "name": "https://selinc.com/support/security-notifications/external-reports/" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "source": { "discovery": "UNKNOWN" }, "credits": [ { "lang": "en", "value": "Sushant Mane, Parul Sindhwad, Imran Jamadar & Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai, India." } ], "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.1" } ] } }