{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2023-0754", "ASSIGNER": "ics-cert@hq.dhs.gov", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-190 Integer Overflow or Wraparound", "cweId": "CWE-190" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "PTC", "product": { "product_data": [ { "product_name": "ThingWorx Edge C-SDK", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v2.2.12.1052 " } ] } }, { "product_name": "ThingWorx Edge MicroServer (EMS)", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v5.4.10.0 " } ] } }, { "product_name": "Kepware KEPServerEX", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v6.12 " } ] } }, { "product_name": "ThingWorx Kepware Server ", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v6.12 " } ] } }, { "product_name": "ThingWorx Industrial Connectivity", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions " } ] } }, { "product_name": "ThingWorx Kepware Edge", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v1.5" } ] } } ] } }, { "vendor_name": "Microsoft", "product": { "product_data": [ { "product_name": ".NET-SDK", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v5.8.4.971 " } ] } } ] } }, { "vendor_name": "Rockwell Automation ", "product": { "product_data": [ { "product_name": "KEPServer Enterprise ", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v6.12" } ] } } ] } }, { "vendor_name": "General Electric ", "product": { "product_data": [ { "product_name": "Digital Industrial Gateway Server ", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v7.612" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01", "refsource": "MISC", "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "source": { "discovery": "EXTERNAL" }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "
PTC has released the following resolutions:
\n\nUpdate the impacted product to the latest version:
\n\n\u00b7 \nThingWorx Edge C-SDK: 3.0.0 or later.
\n\n\u00b7 \nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.
\n\n\u00b7 \n.NET-SDK: v5.8.5 or later.
\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:
\n\n\u00b7 \nKepware KEPServerEX: v6.13 or later.
\n\n\u00b7 \nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.
\n\n\u00b7 \nThingWorx Kepware Edge: v1.6 or later.
\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use:
\n\n\u00b7 \nRockwell Automation KEPServer Enterprise: v6.13\nor later.
\n\n\u00b7 \nGE Digital Industrial Gateway Server: v7.613 or\nlater.
\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.
\n\n\n\n\n\n