{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2023-0754", "ASSIGNER": "ics-cert@hq.dhs.gov", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-190 Integer Overflow or Wraparound", "cweId": "CWE-190" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "PTC", "product": { "product_data": [ { "product_name": "ThingWorx Edge C-SDK", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v2.2.12.1052 " } ] } }, { "product_name": "ThingWorx Edge MicroServer (EMS)", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v5.4.10.0 " } ] } }, { "product_name": "Kepware KEPServerEX", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v6.12 " } ] } }, { "product_name": "ThingWorx Kepware Server ", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v6.12 " } ] } }, { "product_name": "ThingWorx Industrial Connectivity", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions " } ] } }, { "product_name": "ThingWorx Kepware Edge", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v1.5" } ] } } ] } }, { "vendor_name": "Microsoft", "product": { "product_data": [ { "product_name": ".NET-SDK", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v5.8.4.971 " } ] } } ] } }, { "vendor_name": "Rockwell Automation ", "product": { "product_data": [ { "product_name": "KEPServer Enterprise ", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v6.12" } ] } } ] } }, { "vendor_name": "General Electric ", "product": { "product_data": [ { "product_name": "Digital Industrial Gateway Server ", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "v7.612" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01", "refsource": "MISC", "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "source": { "discovery": "EXTERNAL" }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "

PTC has released the following resolutions:

\n\n

Update the impacted product to the latest version:

\n\n

\u00b7        \nThingWorx Edge C-SDK: 3.0.0 or later.

\n\n

\u00b7        \nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.

\n\n

\u00b7        \n.NET-SDK: v5.8.5 or later.

\n\n

For Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:

\n\n

\u00b7        \nKepware KEPServerEX: v6.13 or later.

\n\n

\u00b7        \nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.

\n\n

\u00b7        \nThingWorx Kepware Edge: v1.6 or later.

\n\n

The following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use:

\n\n

\u00b7        \nRockwell Automation KEPServer Enterprise: v6.13\nor later.

\n\n

\u00b7        \nGE Digital Industrial Gateway Server: v7.613 or\nlater.

\n\n

For\nmore information see PTC\u2019s Customer Support Article\n.

\n\n\n\n\n\n
" } ], "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n" } ], "credits": [ { "lang": "en", "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA." } ], "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ] } }