{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2024-25136", "ASSIGNER": "ics-cert@hq.dhs.gov", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "\nThere is a function in AutomationDirect C-MORE EA9 HMI that allows an attacker to send a relative path in the URL without proper sanitizing of the content.\n\n" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Path Traversal", "cweId": "CWE-22" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "AutomationDirect", "product": { "product_data": [ { "product_name": "C-MORE EA9 HMI EA9-T6CL", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-T7CL", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA0-T7CL-R", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-T8CL", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-T10CL", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-T10WCL", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-T12CL", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-T15CL", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-T15CL-R", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-RHMI", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } }, { "product_name": "C-MORE EA9 HMI EA9-PGMSW", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "6.77" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://https://www.cisa.gov/news-events/ics-advisories/icsa-24-086-01", "refsource": "MISC", "name": "https://https://www.cisa.gov/news-events/ics-advisories/icsa-24-086-01" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "source": { "advisory": "ICSA-24-086-01", "discovery": "EXTERNAL" }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nAutomationDirect recommends that users update C-MORE EA9 HMI to V6.78.\n\n
" } ], "value": "\nAutomationDirect recommends that users update C-MORE EA9 HMI to V6.78 https://www.automationdirect.com/support/software-downloads .\n\n" } ], "credits": [ { "lang": "en", "value": "Tomer Goldschmidt of Claroty Research - Team82 reported these vulnerabilities to CISA." } ], "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ] } }