{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2023-34999", "ASSIGNER": "psirt@bosch.com", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "A command injection vulnerability exists in RTS VLink Virtual Matrix Software Versions v5 (< 5.7.6) and v6 (< 6.5.0) that allows an attacker to perform arbitrary code execution via the admin web interface." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-94 Improper Control of Generation of Code ('Code Injection')", "cweId": "CWE-94" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "RTS", "product": { "product_data": [ { "product_name": "VLink Virtual Matrix Software", "version": { "version_data": [ { "version_affected": "<", "version_name": "5.0.0", "version_value": "5.7.6" }, { "version_affected": "<", "version_name": "6.0.0", "version_value": "6.5.0" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-893251-BT.html", "refsource": "MISC", "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-893251-BT.html" } ] }, "impact": { "cvss": [ { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH" } ] } }