{ "data_type": "CVE", "data_format": "MITRE", "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2019-5140", "ASSIGNER": "talos-cna@cisco.com", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "n/a", "product": { "product_data": [ { "product_name": "Moxa", "version": { "version_data": [ { "version_value": "Moxa AWK-3131A firmware version 1.13" } ] } } ] } } ] } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" } ] } ] }, "references": { "reference_data": [ { "refsource": "MISC", "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0929", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0929" } ] }, "description": { "description_data": [ { "lang": "eng", "value": "An exploitable command injection vulnerability exists in the iwwebs functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted diagnostic script file name can cause user input to be reflected in a subsequent iwsystem call, resulting in remote control over the device. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 8.8, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } }