{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2023-42128", "ASSIGNER": "zdi-disclosures@trendmicro.com", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "Magnet Forensics AXIOM Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Magnet Forensics AXIOM. User interaction is required to exploit this vulnerability in that the target must acquire data from a malicious mobile device.\n\nThe specific flaw exists within the Android device image acquisition functionality. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-21255." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')", "cweId": "CWE-78" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Magnet Forensics", "product": { "product_data": [ { "product_name": "AXIOM", "version": { "version_data": [ { "version_affected": "=", "version_value": "7.4.0.36841" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1533/", "refsource": "MISC", "name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1533/" } ] }, "source": { "lang": "en", "value": "Andrew Clark IV" }, "impact": { "cvss": [ { "version": "3.0", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "baseScore": 8, "baseSeverity": "HIGH" } ] } }