{ "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2021-09-30T21:02:00.000Z", "ID": "CVE-2021-38394", "STATE": "PUBLIC", "TITLE": "Missing Protection against Hardware Reverse Engineering Using Integrated Circuit Imaging Techniques for Boston Scientific Zoom Latitude" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ZOOM LATITUDE", "version": { "version_data": [ { "version_value": "Model 3120" } ] } } ] }, "vendor_name": "Boston Scientific" } ] } }, "credit": [ { "lang": "eng", "value": "Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH M\u00fcnster University of Applied Sciences, Christian Dresen - FH M\u00fcnster University of Applied Sciences, and Markus Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices and reported them to Boston Scientific." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An attacker with physical access to the device can extract the binary that checks for the hardware key and reverse engineer it, which could be used to create a physical duplicate of a valid hardware key. The hardware key allows access to special settings when inserted." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "PHYSICAL", "availabilityImpact": "LOW", "baseScore": 6.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-1278 " } ] } ] }, "references": { "reference_data": [ { "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01", "name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01" } ] }, "source": { "advisory": "ICSMA-21-273-01", "defect": [ "CWE-1278" ], "discovery": "EXTERNAL" }, "work_around": [ { "lang": "eng", "value": "Boston Scientific is in the process of transitioning all users to a replacement programmer with enhanced security, the LATITUDE Programming System, Model 3300. Boston Scientific will not issue a product update to address the identified vulnerabilities in the ZOOM LATITUDE Programming System, Model 3120." } ] }