{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2023-31158", "ASSIGNER": "security@selinc.com", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "\nAn Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.\n\n\n\n\n\nSee SEL Service Bulletin dated 2022-11-15 for more details.\n\n\n" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')", "cweId": "CWE-79" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Schweitzer Engineering Laboratories", "product": { "product_data": [ { "product_name": "SEL-3505", "version": { "version_data": [ { "version_affected": "<", "version_name": "R132-V0", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-3505-3", "version": { "version_data": [ { "version_affected": "<", "version_name": "R132-V0", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-3530", "version": { "version_data": [ { "version_affected": "<", "version_name": "R132-V0", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-3530-4", "version": { "version_data": [ { "version_affected": "<", "version_name": "R132-V0", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-3532", "version": { "version_data": [ { "version_affected": "<", "version_name": "R132-V0", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-3555", "version": { "version_data": [ { "version_affected": "<", "version_name": "R134-V0", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-3560S", "version": { "version_data": [ { "version_affected": "<", "version_name": "R144-V2", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-3560E", "version": { "version_data": [ { "version_affected": "<", "version_name": "R144-V2", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-2241 RTAC module", "version": { "version_data": [ { "version_affected": "<", "version_name": "R132-V0", "version_value": "R150-V2" } ] } }, { "product_name": "SEL-3350", "version": { "version_data": [ { "version_affected": "<", "version_name": "R148-V0", "version_value": "R150-V2" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://selinc.com/support/security-notifications/external-reports/", "refsource": "MISC", "name": "https://selinc.com/support/security-notifications/external-reports/" }, { "url": "https://www.nozominetworks.com/blog/", "refsource": "MISC", "name": "https://www.nozominetworks.com/blog/" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "source": { "discovery": "EXTERNAL" }, "credits": [ { "lang": "en", "value": "Andrea Palanca, Nozomi Networks" } ], "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.1" } ] } }