{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2021-20599", "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-319 Cleartext Transmission of Sensitive Information", "cweId": "CWE-319" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Mitsubishi Electric Corporation", "product": { "product_data": [ { "product_name": "MELSEC iQ-R Series Safety CPU R08SFCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "Firmware versions \"26\" and prior" } ] } }, { "product_name": "MELSEC iQ-R series Safety CPU R16SFCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "Firmware versions \"26\" and prior" } ] } }, { "product_name": "MELSEC iQ-R series Safety CPU R32SFCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "Firmware versions \"26\" and prior" } ] } }, { "product_name": "MELSEC iQ-R series Safety CPU R120SFCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "Firmware versions \"26\" and prior" } ] } }, { "product_name": "MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "Firmware versions \"11\" and prior" } ] } }, { "product_name": "MELSEC iQ-R series SIL2 Process CPU R16PSFCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "Firmware versions \"11\" and prior" } ] } }, { "product_name": "MELSEC iQ-R series SIL2 Process CPU R32PSFCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "Firmware versions \"11\" and prior" } ] } }, { "product_name": "MELSEC iQ-R series SIL2 Process CPU R120PSFCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "Firmware versions \"11\" and prior" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf", "refsource": "MISC", "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf" }, { "url": "https://jvn.jp/vu/JVNVU98578731", "refsource": "MISC", "name": "https://jvn.jp/vu/JVNVU98578731" }, { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03", "refsource": "MISC", "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "source": { "discovery": "UNKNOWN" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" } ] } }