{ "CVE_data_meta" : { "ASSIGNER" : "talos-cna@cisco.com", "DATE_PUBLIC" : "2018-07-26T00:00:00", "ID" : "CVE-2018-3912", "STATE" : "PUBLIC" }, "affects" : { "vendor" : { "vendor_data" : [ { "product" : { "product_data" : [ { "product_name" : "SmartThings Hub STH-ETH-250", "version" : { "version_data" : [ { "version_value" : "Firmware version 0.20.17" } ] } } ] }, "vendor_name" : "Samsung" } ] } }, "data_format" : "MITRE", "data_type" : "CVE", "data_version" : "4.0", "description" : { "description_data" : [ { "lang" : "eng", "value" : "On Samsung SmartThings Hub STH-ETH-250 devices with firmware version 0.20.17, the video-core process insecurely extracts the fields from the \"shard\" table of its SQLite database, leading to a buffer overflow on the stack. The strcpy call overflows the destination buffer, which has a size of 128 bytes. An attacker can send an arbitrarily long \"secretKey\" value in order to exploit this vulnerability." } ] }, "problemtype" : { "problemtype_data" : [ { "description" : [ { "lang" : "eng", "value" : "Classic Buffer Overflow" } ] } ] }, "references" : { "reference_data" : [ { "name" : "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0581", "refsource" : "MISC", "url" : "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0581" } ] } }