{ "CVE_data_meta" : { "ASSIGNER" : "ics-cert@hq.dhs.gov", "DATE_PUBLIC" : "2018-04-26T00:00:00", "ID" : "CVE-2018-8839", "STATE" : "PUBLIC" }, "affects" : { "vendor" : { "vendor_data" : [ { "product" : { "product_data" : [ { "product_name" : "PMSoft", "version" : { "version_data" : [ { "version_value" : "v 2.10 or prior." } ] } } ] }, "vendor_name" : "Delta Electronics" } ] } }, "data_format" : "MITRE", "data_type" : "CVE", "data_version" : "4.0", "description" : { "description_data" : [ { "lang" : "eng", "value" : "Delta PMSoft versions 2.10 and prior have multiple stack-based buffer overflow vulnerabilities where a .ppm file can introduce a value larger than is readable by PMSoft's fixed-length stack buffer. This can cause the buffer to be overwritten, which may allow arbitrary code execution or cause the application to crash. CVSS v3 base score: 7.1; CVSS vector string: AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H. Delta Electronics recommends affected users update to at least PMSoft v2.11, which was made available as of March 22, 2018, or the latest available version." } ] }, "problemtype" : { "problemtype_data" : [ { "description" : [ { "lang" : "eng", "value" : "Stack-based buffer overflow CWE-121" } ] } ] }, "references" : { "reference_data" : [ { "name" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-116-01", "refsource" : "MISC", "url" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-116-01" }, { "name" : "104013", "refsource" : "BID", "url" : "http://www.securityfocus.com/bid/104013" } ] } }