{ "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-07-30T16:50:00.000Z", "ID": "CVE-2020-14523", "STATE": "PUBLIC", "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CW Configurator", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Version 1.010L" } ] } }, { "product_name": "FR Configurator2", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Version 1.22Y" } ] } }, { "product_name": "GX Works2", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Version 1.595V" } ] } }, { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Version 1.063R" } ] } }, { "product_name": "MELSOFT iQ AppPortal", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Version 1.17T" } ] } }, { "product_name": "MELSOFT Navigator", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Version2.70Y" } ] } }, { "product_name": "MI Configurator", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MR Configurator2", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Version 1.110Q" } ] } }, { "product_name": "MT Works2", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Versions 1.156N" } ] } }, { "product_name": "MX Component", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Version 4.20W" } ] } }, { "product_name": "RT ToolBox3", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Versions 1.70Y" } ] } }, { "product_name": "MELSEC iQ-R Series Motion Module", "version": { "version_data": [ { "version_affected": "<=", "version_value": "Versions 10" } ] } } ] }, "vendor_name": "Mitsubishi Electric" } ] } }, "credit": [ { "lang": "eng", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')" } ] } ] }, "references": { "reference_data": [ { "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03", "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "refsource": "MISC", "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "refsource": "MISC", "name": "https://jvn.jp/vu/JVNVU90224831/", "url": "https://jvn.jp/vu/JVNVU90224831/" } ] }, "solution": [ { "lang": "eng" } ], "source": { "advisory": "ICSA-20-212-03", "discovery": "UNKNOWN" } }