{ "data_type": "CVE", "data_format": "MITRE", "data_version": "4.0", "generator": { "engine": "Vulnogram 0.0.9" }, "CVE_data_meta": { "ID": "CVE-2020-12516", "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2020-12-09T09:00:00.000Z", "TITLE": "WAGO: PLC families 750-88x and 750-352 prone to DoS attack", "AKA": "", "STATE": "PUBLIC" }, "source": { "defect": [ "VDE-2020-042" ], "advisory": "VDE-2020-042", "discovery": "UNKNOWN" }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "WAGO", "product": { "product_data": [ { "product_name": "750-331/xxx-xxx", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-352", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-829", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-831/xxx-xxx", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-852", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-880/xxx-xxx", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-881", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-882", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-885", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } }, { "product_name": "750-889", "version": { "version_data": [ { "version_value": "FW1<=FW10" } ] } } ] } } ] } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400 Uncontrolled Resource Consumption" } ] } ] }, "description": { "description_data": [ { "lang": "eng", "value": "Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack." } ] }, "references": { "reference_data": [ { "refsource": "MISC", "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-308-01", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-308-01" }, { "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-042", "name": "https://cert.vde.com/en-us/advisories/vde-2020-042" } ] }, "configuration": [], "impact": { "cvss": { "version": "3.1", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH" } }, "exploit": [], "work_around": [ { "lang": "eng", "value": "Restrict network access to the device.\nDo not directly connect the device to the internet\nDisable unused TCP/UDP-ports" } ], "solution": [ { "lang": "eng", "value": "Update the device to the latest FW version." } ], "credit": [ { "lang": "eng", "value": " These vulnerabilities were reported to WAGO by: William Knowles, Applied Risk. Coordination done by CERT@VDE." } ] }