{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2024-2891", "ASSIGNER": "cna@vuldb.com", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "deu", "value": "Es wurde eine Schwachstelle in Tenda AC7 15.03.06.44 gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion formQuickIndex der Datei /goform/QuickIndex. Mittels Manipulieren des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121 Stack-based Buffer Overflow", "cweId": "CWE-121" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Tenda", "product": { "product_data": [ { "product_name": "AC7", "version": { "version_data": [ { "version_affected": "=", "version_value": "15.03.06.44" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://vuldb.com/?id.257934", "refsource": "MISC", "name": "https://vuldb.com/?id.257934" }, { "url": "https://vuldb.com/?ctiid.257934", "refsource": "MISC", "name": "https://vuldb.com/?ctiid.257934" }, { "url": "https://vuldb.com/?submit.300354", "refsource": "MISC", "name": "https://vuldb.com/?submit.300354" }, { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md", "refsource": "MISC", "name": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md" } ] }, "credits": [ { "lang": "en", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "impact": { "cvss": [ { "version": "3.1", "baseScore": 8.8, "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseSeverity": "HIGH" }, { "version": "3.0", "baseScore": 8.8, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseSeverity": "HIGH" }, { "version": "2.0", "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C" } ] } }