{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2025-23400", "ASSIGNER": "productcert@siemens.com", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer", "cweId": "CWE-119" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Siemens", "product": { "product_data": [ { "product_name": "Teamcenter Visualization V14.3", "version": { "version_data": [ { "version_affected": "<", "version_name": "0", "version_value": "V14.3.0.13" } ] } }, { "product_name": "Teamcenter Visualization V2312", "version": { "version_data": [ { "version_affected": "<", "version_name": "0", "version_value": "V2312.0009" } ] } }, { "product_name": "Teamcenter Visualization V2406", "version": { "version_data": [ { "version_affected": "<", "version_name": "0", "version_value": "V2406.0007" } ] } }, { "product_name": "Teamcenter Visualization V2412", "version": { "version_data": [ { "version_affected": "<", "version_name": "0", "version_value": "V2412.0002" } ] } }, { "product_name": "Tecnomatix Plant Simulation V2302", "version": { "version_data": [ { "version_affected": "<", "version_name": "0", "version_value": "V2302.0021" } ] } }, { "product_name": "Tecnomatix Plant Simulation V2404", "version": { "version_data": [ { "version_affected": "<", "version_name": "0", "version_value": "V2404.0010" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html", "refsource": "MISC", "name": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html" } ] }, "impact": { "cvss": [ { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH" } ] } }