{ "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", "CVE_data_meta": { "ID": "CVE-2024-22182", "ASSIGNER": "ics-cert@hq.dhs.gov", "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", "value": "** UNSUPPPORTED WHEN ASSIGNED ** A remote, unauthenticated attacker may be able to send crafted messages \nto the web server of the Commend WS203VICM causing the system to \nrestart, interrupting service.\n\n" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-88 Argument Injection", "cweId": "CWE-88" } ] } ] }, "affects": { "vendor": { "vendor_data": [ { "vendor_name": "Commend", "product": { "product_data": [ { "product_name": "WS203VICM", "version": { "version_data": [ { "version_affected": "<=", "version_name": "0", "version_value": "1.7" } ] } } ] } } ] } }, "references": { "reference_data": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-051-01", "refsource": "MISC", "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-051-01" }, { "url": "https://clibrary-online.commend.com/en/cyber-security/security-advisories.html", "refsource": "MISC", "name": "https://clibrary-online.commend.com/en/cyber-security/security-advisories.html" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "source": { "advisory": "ICSA-24-051-01", "discovery": "EXTERNAL" }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\nAlthough this is an end-of-life product, Commend has created new firmware version WS-CM 2.0  to\n address the first two issues. The new firmware can be loaded via the \nprogram \"IP Station Config\". To install the firmware, follow the \ninstructions below:
    \n
  1. Log in to the Commend web-portal.
  2. \n
  3. Download and extract the \"Terminals Software Package\".
  4. \n
  5. In \"IP Station Config\", select the stations to be updated in the table.
  6. \n
  7. Go to: Menu Station > Firmware Download
  8. \n
  9. Select the file \"WS-CM 2.0.geh\" from the folder \"WS-CM\" and click on the button Open.
  10. \n
\n

For additional information, please visit CSA-2024-42 on Commend's cybersecurity website.

\n\n
" } ], "value": "Although this is an end-of-life product, Commend has created new firmware version WS-CM 2.0 https://clibrary-online.commend.com/ \u00a0\u00a0to\n address the first two issues. The new firmware can be loaded via the \nprogram \"IP Station Config\". To install the firmware, follow the \ninstructions below:\n * Log in to the Commend web-portal.\n\n * Download and extract the \"Terminals Software Package\".\n\n * In \"IP Station Config\", select the stations to be updated in the table.\n\n * Go to: Menu Station > Firmware Download\n\n * Select the file \"WS-CM 2.0.geh\" from the folder \"WS-CM\" and click on the button Open.\n\n\nFor additional information, please visit CSA-2024-42 on Commend's cybersecurity website. https://clibrary-online.commend.com/en/cyber-security/security-advisories.html \n\n\n\n\n" } ], "credits": [ { "lang": "en", "value": "Aar\u00f3n Flecha Men\u00e9ndez of S21sec reported these vulnerabilities to CISA." } ], "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" } ] } }