cvelist/2022/1xxx/CVE-2022-1300.json
2022-05-02 12:16:27 +02:00

124 lines
4.5 KiB
JSON

{
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2022-05-02T10:00:00.000Z",
"ID": "CVE-2022-1300",
"STATE": "PUBLIC",
"TITLE": "Missing authentication in TRUMPF products may result in corruption of data"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "TruTops Boost",
"version": {
"version_data": [
{
"version_affected": ">=",
"version_value": "V13.01"
},
{
"version_affected": "<=",
"version_value": "V13.05"
},
{
"version_affected": "=",
"version_value": "V13.08.21"
}
]
}
},
{
"product_name": "TruTops Fab (incl. TruTops Monitor)",
"version": {
"version_data": [
{
"version_affected": ">=",
"version_value": "V22.01."
},
{
"version_affected": "<=",
"version_value": "V22.05."
},
{
"version_affected": "=",
"version_value": "V22.08.21"
}
]
}
}
]
},
"vendor_name": "TRUMPF"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple Version of TRUMPF TruTops products expose a service function without necessary authentication. Execution of this function may result in unauthorized access to change of data or disruption of the whole service."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2022-016/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2022-016/"
}
]
},
"solution": [
{
"lang": "eng",
"value": "Use the updated versions of the TRUMPF products that will be available via your service channel shortly or the hotfix in the reference."
}
],
"source": {
"advisory": "VDE-2022-016",
"defect": [
"CERT@VDE#64101"
],
"discovery": "INTERNAL"
}
}