cvelist/2019/6xxx/CVE-2019-6469.json
2019-11-02 03:00:57 +00:00

110 lines
4.0 KiB
JSON

{
"CVE_data_meta": {
"ASSIGNER": "security-officer@isc.org",
"DATE_PUBLIC": "2019-05-29T23:00:00.000Z",
"ID": "CVE-2019-6469",
"STATE": "PUBLIC",
"TITLE": "BIND Supported Preview Edition can exit with an assertion failure if ECS is in use"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BIND 9 Supported Preview Edition",
"version": {
"version_data": [
{
"version_name": "BIND 9",
"version_value": "BIND 9.10.5-S1 -> 9.11.6-S1 of BIND 9 Supported Preview Edition."
}
]
}
}
]
},
"vendor_name": "ISC"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "ISC would like to thank Quad9 for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An error in the EDNS Client Subnet (ECS) feature for recursive resolvers can cause BIND to exit with an assertion failure when processing a response that has malformed RRSIGs. Versions affected: BIND 9.10.5-S1 -> 9.11.6-S1 of BIND 9 Supported Preview Edition."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "An attacker who is able to cause a server to perform a query whose answer will be accompanied by malformed RRSIGs can deliberately cause a server to exit if it is using the recursive ECS feature."
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.isc.org/docs/cve-2019-6469",
"refsource": "CONFIRM",
"url": "https://kb.isc.org/docs/cve-2019-6469"
},
{
"refsource": "CONFIRM",
"name": "https://support.f5.com/csp/article/K39751401?utm_source=f5support&utm_medium=RSS",
"url": "https://support.f5.com/csp/article/K39751401?utm_source=f5support&utm_medium=RSS"
}
]
},
"solution": [
{
"lang": "eng",
"value": "Upgrade to the patched release most closely related to your current version of BIND:\n\nBIND Supported Preview Edition is a special feature preview branch of BIND provided to eligible ISC support customers.\n\n>= BIND 9.11.7-S1\n"
}
],
"source": {
"discovery": "USER"
},
"work_around": [
{
"lang": "eng",
"value": "Only servers which have enabled the EDNS Client Subnet (ECS) feature can be affected by this defect; it can be prevented by disabling ECS options in the server's configuration."
}
]
}