"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-28393",
"ASSIGNER": "productcert@siemens.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "SCALANCE XM-400, XR-500",
"version": {
"version_data": [
{
"version_value": "All versions prior to v6.4"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "INCORRECT CALCULATION CWE-682"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-10",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-10"
},
{
"refsource": "MISC",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4)."
}
]
}
}