"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2024-37992",
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected devices does not properly handle the error in case of exceeding characters while setting SNMP leading to the restart of the application."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-703: Improper Check or Handling of Exceptional Conditions",
|
|
"cweId": "CWE-703"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Siemens",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "SIMATIC Reader RF610R CMIIT",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF610R ETSI",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF610R FCC",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF615R CMIIT",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF615R ETSI",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF615R FCC",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF650R ARIB",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF650R CMIIT",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF650R ETSI",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF650R FCC",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF680R ARIB",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF680R CMIIT",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF680R ETSI",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF680R FCC",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF685R ARIB",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF685R CMIIT",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF685R ETSI",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC Reader RF685R FCC",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V4.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF1140R",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V1.1"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF1170R",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V1.1"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF166C",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V2.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF185C",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V2.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF186C",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V2.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF186CI",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V2.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF188C",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V2.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF188CI",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V2.2"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "SIMATIC RF360R",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V2.2"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html"
|
|
}
|
|
]
|
|
},
|
|
"impact": {
|
|
"cvss": [
|
|
{
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
|
|
"baseScore": 4.9,
|
|
"baseSeverity": "MEDIUM"
|
|
}
|
|
]
|
|
}
|
|
} |