cvelist/2023/43xxx/CVE-2023-43488.json
2023-10-25 17:39:47 +00:00

104 lines
3.8 KiB
JSON

{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2023-43488",
"ASSIGNER": "psirt@bosch.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "The vulnerability allows a low privileged (untrusted) application to\r\nmodify a critical system property that should be denied, in order to enable the ADB (Android Debug Bridge) protocol to be exposed on the network, exploiting it to gain a privileged shell on the device without requiring the physical access through USB."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-862 Missing Authorization",
"cweId": "CWE-862"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Rexroth",
"product": {
"product_data": [
{
"product_name": "ctrlX HMI Web Panel - WR21 (WR2107)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "ctrlX HMI Web Panel - WR21 (WR2110)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
},
{
"product_name": "ctrlX HMI Web Panel - WR21 (WR2115)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"refsource": "MISC",
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
},
"impact": {
"cvss": [
{
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:L",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"availabilityImpact": "LOW",
"baseScore": 7.9,
"baseSeverity": "HIGH"
}
]
}
}