cvelist/2024/43xxx/CVE-2024-43655.json
2025-01-09 08:01:02 +00:00

113 lines
4.4 KiB
JSON

{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2024-43655",
"ASSIGNER": "csirt@divd.nl",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root\n\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
"cweId": "CWE-78"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-250: Execution with Unnecessary Privileges",
"cweId": "CWE-250"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "OWASP-A03: Injection"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Iocharger",
"product": {
"product_data": [
{
"product_name": "Iocharger firmware for AC models",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "0",
"version_value": "24120701"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://csirt.divd.nl/DIVD-2024-00035/",
"refsource": "MISC",
"name": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"url": "https://csirt.divd.nl/CVE-2024-43655/",
"refsource": "MISC",
"name": "https://csirt.divd.nl/CVE-2024-43655/"
},
{
"url": "https://iocharger.com",
"refsource": "MISC",
"name": "https://iocharger.com"
}
]
},
"generator": {
"engine": "Vulnogram 0.2.0"
},
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"credits": [
{
"lang": "en",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"value": "Frank Breedijk (DIVD)"
}
]
}