mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-07-29 05:56:59 +00:00
123 lines
5.2 KiB
JSON
123 lines
5.2 KiB
JSON
{
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "cybersecurity@hitachienergy.com",
|
|
"DATE_PUBLIC": "2022-09-06T14:30:00.000Z",
|
|
"ID": "CVE-2022-1778",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by an administrator access."
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "MicroSCADA X SYS600",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "10"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "10.1"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "10.1.1"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "10.2"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "10.2.1"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "10.3"
|
|
},
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "10.3.1"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Hitachi Energy"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*"
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-20 Improper Input Validation"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch",
|
|
"refsource": "CONFIRM",
|
|
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch"
|
|
}
|
|
]
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Remediated in SYS600 10.4 \nUpdate to at least SYS600 version 10.4."
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "INTERNAL"
|
|
},
|
|
"work_around": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Apply general mitigation factors as specify in the advisory. "
|
|
}
|
|
]
|
|
} |