mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-07-29 05:56:59 +00:00
90 lines
3.3 KiB
JSON
90 lines
3.3 KiB
JSON
{
|
|
"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2022-29034",
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code.\r\n\r\nThis could allow attackers to perform reflected cross-site scripting (XSS) attacks."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
|
|
"cweId": "CWE-79"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Siemens",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "SINEMA Remote Connect Server",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V3.1"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf"
|
|
},
|
|
{
|
|
"url": "http://seclists.org/fulldisclosure/2022/Jun/35",
|
|
"refsource": "MISC",
|
|
"name": "http://seclists.org/fulldisclosure/2022/Jun/35"
|
|
},
|
|
{
|
|
"url": "http://packetstormsecurity.com/files/167554/SIEMENS-SINEMA-Remote-Connect-3.0.1.0-01.01.00.02-Cross-Site-Scripting.html",
|
|
"refsource": "MISC",
|
|
"name": "http://packetstormsecurity.com/files/167554/SIEMENS-SINEMA-Remote-Connect-3.0.1.0-01.01.00.02-Cross-Site-Scripting.html"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html"
|
|
}
|
|
]
|
|
},
|
|
"impact": {
|
|
"cvss": [
|
|
{
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C",
|
|
"baseScore": 6.1,
|
|
"baseSeverity": "MEDIUM"
|
|
}
|
|
]
|
|
}
|
|
} |