"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2017-2685",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SINUMERIK Integrate Operate Clients 2.x and 3.x",
"version": {
"version_data": [
{
"version_value": "SINUMERIK Integrate Operate Clients 2.x and 3.x"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-693: Protection Mechanism Failure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "96519",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/96519"
},
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-934525.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-934525.pdf"
}
]
}
}