mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-08-04 08:44:25 +00:00
96 lines
3.8 KiB
JSON
96 lines
3.8 KiB
JSON
{
|
|
"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2024-43660",
|
|
"ASSIGNER": "csirt@divd.nl",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "The CGI script <redacted>.sh can be used to download any file on the filesystem.\n\nThis issue affects Iocharger firmware for AC model chargers beforeversion 24120701.\n\nLikelihood: High, but credentials required.\n\nImpact: Critical \u2013 The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.\n\nCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y\nCVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y)."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-552 Files or Directories Accessible to External Parties",
|
|
"cweId": "CWE-552"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Iocharger",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Iocharger firmware for AC models",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "24120701"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://csirt.divd.nl/DIVD-2024-00035/",
|
|
"refsource": "MISC",
|
|
"name": "https://csirt.divd.nl/DIVD-2024-00035/"
|
|
},
|
|
{
|
|
"url": "https://csirt.divd.nl/CVE-2024-43660/",
|
|
"refsource": "MISC",
|
|
"name": "https://csirt.divd.nl/CVE-2024-43660/"
|
|
},
|
|
{
|
|
"url": "https://iocharger.com",
|
|
"refsource": "MISC",
|
|
"name": "https://iocharger.com"
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.2.0"
|
|
},
|
|
"source": {
|
|
"advisory": "DIVD-2024-00035",
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Wilco van Beijnum"
|
|
},
|
|
{
|
|
"lang": "en",
|
|
"value": "Harm van den Brink (DIVD)"
|
|
},
|
|
{
|
|
"lang": "en",
|
|
"value": "Frank Breedijk (DIVD)"
|
|
}
|
|
]
|
|
} |