cvelist/2024/0xxx/CVE-2024-0298.json
2024-01-08 05:00:40 +00:00

105 lines
3.9 KiB
JSON

{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2024-0298",
"ASSIGNER": "cna@vuldb.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was found in Totolink N200RE 9.3.5u.6139_B20201216. It has been classified as critical. Affected is the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-249864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "deu",
"value": "Es wurde eine kritische Schwachstelle in Totolink N200RE 9.3.5u.6139_B20201216 ausgemacht. Betroffen hiervon ist die Funktion setDiagnosisCfg der Datei /cgi-bin/cstecgi.cgi. Durch Beeinflussen des Arguments ip mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78 OS Command Injection",
"cweId": "CWE-78"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Totolink",
"product": {
"product_data": [
{
"product_name": "N200RE",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "9.3.5u.6139_B20201216"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://vuldb.com/?id.249864",
"refsource": "MISC",
"name": "https://vuldb.com/?id.249864"
},
{
"url": "https://vuldb.com/?ctiid.249864",
"refsource": "MISC",
"name": "https://vuldb.com/?ctiid.249864"
},
{
"url": "https://github.com/jylsec/vuldb/blob/main/TOTOLINK/N200RE/setDiagnosisCfg/README.md",
"refsource": "MISC",
"name": "https://github.com/jylsec/vuldb/blob/main/TOTOLINK/N200RE/setDiagnosisCfg/README.md"
}
]
},
"credits": [
{
"lang": "en",
"value": "jylsec (VulDB User)"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"baseScore": 7.3,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "HIGH"
},
{
"version": "3.0",
"baseScore": 7.3,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "HIGH"
},
{
"version": "2.0",
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P"
}
]
}
}