mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-07-29 05:56:59 +00:00
105 lines
4.4 KiB
JSON
105 lines
4.4 KiB
JSON
{
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "CybersecurityCOE@eaton.com",
|
|
"DATE_PUBLIC": "2022-04-01T10:56:00.000Z",
|
|
"ID": "CVE-2021-23284",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "Security issues in Eaton Intelligent Power Manager Infrastructure"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Intelligent Power Manager Infrastructure (IPM Infrastructure)",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<=",
|
|
"version_name": "all",
|
|
"version_value": "1.5.0plus205"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "Eaton"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"credit": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23284 \u2013 Micheal Heinzl via ICS-Cert"
|
|
}
|
|
],
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to Stored Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions."
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 5.7,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"refsource": "MISC",
|
|
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf",
|
|
"name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf"
|
|
},
|
|
{
|
|
"refsource": "MISC",
|
|
"url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf.",
|
|
"name": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf."
|
|
}
|
|
]
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification. Check References section. \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details."
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "EXTERNAL"
|
|
}
|
|
} |