"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"DATE_PUBLIC": "2020-08-20T16:34:00.000Z",
"ID": "CVE-2020-9062",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ProCash 2100xe USB ATM",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "Wincor Probase",
"version_value": "1.1.30"
}
]
}
}
]
},
"vendor_name": "Diebold Nixdorf"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Diebold Nixdorf ProCash 2100xe USB ATMs running Wincor Probase version 1.1.30 do not encrypt, authenticate, or verify the integrity of messages between the CCDM and the host computer, allowing an attacker with physical access to internal ATM components to commit deposit forgery by intercepting and modifying messages to the host computer, such as the amount and value of currency being deposited."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-353 Missing Support for Integrity Check"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-311 Missing Encryption of Sensitive Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"url": "https://kb.cert.org/vuls/id/221785",
"name": "https://kb.cert.org/vuls/id/221785"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}