"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2021-20586",
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Robot Controller MELFA FR Series; Robot Controller CR Series; Cooperative Robot ASSISTA",
"version": {
"version_data": [
{
"version_value": "Controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, Controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, Controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, Controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, Controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, Controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, Controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, Controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, Controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions"
},
{
"version_value": "Controller \"CR800-CVD\" of RV-8CRL-D-* all versions, Controller \"CR800-CHD\" of RH-*CRH**-D-* all versions"
},
{
"version_value": "Controller \"CR800-05VD\" of RV-5AS-D-* all versions"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Resource management errors"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-019_en.pdf"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "Resource management errors vulnerability in a robot controller of MELFA FR Series(controller \"CR800-*V*D\" of RV-*FR***-D-* all versions, controller \"CR800-*HD\" of RH-*FRH***-D-* all versions, controller \"CR800-*HRD\" of RH-*FRHR***-D-* all versions, controller \"CR800-*V*R with R16RTCPU\" of RV-*FR***-R-* all versions, controller \"CR800-*HR with R16RTCPU\" of RH-*FRH***-R-* all versions, controller \"CR800-*HRR with R16RTCPU\" of RH-*FRHR***-R-* all versions, controller \"CR800-*V*Q with Q172DSRCPU\" of RV-*FR***-Q-* all versions, controller \"CR800-*HQ with Q172DSRCPU\" of RH-*FRH***-Q-* all versions, controller \"CR800-*HRQ with Q172DSRCPU\" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller \"CR800-CVD\" of RV-8CRL-D-* all versions, controller \"CR800-CHD\" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller \"CR800-05VD\" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error occurs."
}
]
}
}