cvelist/2019/12xxx/CVE-2019-12254.json
2022-05-06 15:29:12 +02:00

151 lines
5.5 KiB
JSON

{
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2019-04-06T10:00:00.000Z",
"ID": "CVE-2019-12254",
"STATE": "PUBLIC",
"TITLE": "TECSON/GOK: Improper Authentication and Access Control on multiple devices"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "e-litro net",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "V6.32"
}
]
}
},
{
"product_name": "LX-Net",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "V6.32"
}
]
}
},
{
"product_name": "LX-Q-Net",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "V6.32"
}
]
}
}
]
},
"vendor_name": "TECSON"
},
{
"product": {
"product_data": [
{
"product_name": "SmartBox 4 LAN",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "V6.3"
}
]
}
},
{
"product_name": "SmartBox 4 LAN PRO",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "V6.3"
}
]
}
}
]
},
"vendor_name": "GOK"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Maxim Rupp (rupp.it) reported this vulnerability to CERT@VDE."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple Tecson Tankspion and GOKs SmartBox 4 products the affected application doesn't properly restrict access to an endpoint that is responsible for saving settings, to a unauthenticated user with limited access rights. Based on the lack of adequately implemented access-control rules, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to change the application settings without authenticating at all, which violates originally laid ACL rules."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2019-012/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2019-012/"
}
]
},
"solution": [
{
"lang": "eng",
"value": "Upgrade to firmware version > 6.32"
}
],
"source": {
"advisory": "VDE-2019-012",
"discovery": "EXTERNAL"
}
}