"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-31T00:00:00",
"ID": "CVE-2018-8844",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "e-Alert Unit (non-medical device)",
"version": {
"version_data": [
{
"version_value": "R2.1 and prior"
}
]
}
}
]
},
"vendor_name": "Philips"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CROSS-SITE REQUEST FORGERY (CSRF) CWE-352"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"refsource": "CONFIRM",
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "105194",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105194"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"
}
]
}
}