"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-12260",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://support2.windriver.com/index.php?page=security-notices",
"refsource": "MISC",
"name": "https://support2.windriver.com/index.php?page=security-notices"
},
{
"refsource": "CONFIRM",
"name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009",
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009"
},
{
"refsource": "CONFIRM",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf"
},
{
"refsource": "CONFIRM",
"name": "https://security.netapp.com/advisory/ntap-20190802-0001/",
"url": "https://security.netapp.com/advisory/ntap-20190802-0001/"
},
{
"refsource": "CONFIRM",
"name": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/",
"url": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/"
},
{
"refsource": "MISC",
"name": "https://support2.windriver.com/index.php?page=cve&on=view&id=CVE-2019-12260",
"url": "https://support2.windriver.com/index.php?page=cve&on=view&id=CVE-2019-12260"
},
{
"refsource": "CONFIRM",
"name": "https://support.f5.com/csp/article/K41190253",
"url": "https://support.f5.com/csp/article/K41190253"
},
{
"refsource": "CONFIRM",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf"
},
{
"refsource": "CONFIRM",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf"
}
]
}
}