"CVE_data_meta": {
|
|
"ASSIGNER": "productsecurity@carrier.com",
|
|
"DATE_PUBLIC": "2022-06-02T22:00:00.000Z",
|
|
"ID": "CVE-2022-31486",
|
|
"STATE": "PUBLIC",
|
|
"TITLE": "Command injection via Advanced Networking route add functionality"
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "LNL-X2210",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "LNL-X2220",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "LNL-X3300",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "LNL-X4420",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "LNL-4420",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.297"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "S2-LP-1501",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "S2-LP-1502",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "S2-LP-2500",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "S2-LP-4502",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "LenelS2"
|
|
},
|
|
{
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "LP1501",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "LP1502",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "LP2500",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "LP4502",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.303"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "EP4502",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "ALL",
|
|
"version_value": "1.297"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"vendor_name": "HID Mercury"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"credit": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Sam Quinn @eAyeP and Steve Povolny @spovolny from Trellix Threat Labs"
|
|
}
|
|
],
|
|
"data_format": "MITRE",
|
|
"data_type": "CVE",
|
|
"data_version": "4.0",
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "An authenticated attacker can send a specially crafted route to the \u201cedit_route.cgi\u201d binary and have it execute shell commands. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.303 for the LP series and 1.297 for the EP series. An attacker with this level of access on the device can monitor all communications sent to and from this device, modify onboard relays, change configuration files, or cause the device to become unstable."
|
|
}
|
|
]
|
|
},
|
|
"generator": {
|
|
"engine": "Vulnogram 0.0.9"
|
|
},
|
|
"impact": {
|
|
"cvss": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-78 OS Command Injection"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"refsource": "MISC",
|
|
"url": "https://www.corporate.carrier.com/product-security/advisories-resources/",
|
|
"name": "https://www.corporate.carrier.com/product-security/advisories-resources/"
|
|
}
|
|
]
|
|
},
|
|
"solution": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Update to the latest version of firmware"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "CARR-PSA-006-0522",
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"work_around": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "Disable the controller's Web Server. \nWhen the controller is configured to disable web access, you cannot remotely login into the controller\u2019s web page.\n1. Login to controller web pages\n2. Go to \u201cUsers\u201d Tab\n3. Near bottom of the Users page, check option to \u201cDisable Web Server\u201d\n4. Then select \u201cSubmit\u201d at the bottom of the page\n5. Then select \u201cApply Settings\u201d tab\n6. And on that page, select button \u201cApply Settings, Reboot\u201d\nThe Controller will apply the new setting and reboot. Web login will be disabled until switch 1 is physically turned ON, on the controller."
|
|
}
|
|
]
|
|
} |