"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"data_format": "MITRE",
|
|
"CVE_data_meta": {
|
|
"ID": "CVE-2023-38527",
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-125: Out-of-bounds Read",
|
|
"cweId": "CWE-125"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Siemens",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Parasolid V34.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V34.1.258"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V35.0",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V35.0.254"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Teamcenter Visualization V14.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V14.1.0.11"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Teamcenter Visualization V14.2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V14.2.0.6"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Teamcenter Visualization V14.3",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V14.3.0.3"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf"
|
|
}
|
|
]
|
|
},
|
|
"impact": {
|
|
"cvss": [
|
|
{
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
]
|
|
}
|
|
} |