mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-07-29 05:56:59 +00:00
132 lines
5.6 KiB
JSON
132 lines
5.6 KiB
JSON
{
|
|
"CVE_data_meta": {
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"ID": "CVE-2022-39152",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"data_format": "MITRE",
|
|
"data_version": "4.0",
|
|
"data_type": "CVE",
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Siemens",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Parasolid V33.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V33.1.262"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V33.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions >= V33.1.262 < V33.1.263"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V34.0",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V34.0.252"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V34.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V34.1.242"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V35.0",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V35.0.161"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Parasolid V35.0",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions >= V35.0.161 < V35.0.164"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Simcenter Femap V2022.1",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V2022.1.3"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Simcenter Femap V2022.2",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_value": "All versions < V2022.2.2"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-787: Out-of-bounds Write"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)"
|
|
}
|
|
]
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"refsource": "MISC",
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
|
|
}
|
|
]
|
|
}
|
|
} |