"ID": "CVE-2022-43513",
|
|
"ASSIGNER": "productcert@siemens.com",
|
|
"STATE": "PUBLIC"
|
|
},
|
|
"description": {
|
|
"description_data": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6 (All versions < V6.0 SP9 Upd4), TeleControl Server Basic V3 (All versions < V3.1.2). The affected components allow to rename license files with user chosen input without authentication.\r\nThis could allow an unauthenticated remote attacker to rename and move files as SYSTEM user."
|
|
}
|
|
]
|
|
},
|
|
"problemtype": {
|
|
"problemtype_data": [
|
|
{
|
|
"description": [
|
|
{
|
|
"lang": "eng",
|
|
"value": "CWE-73: External Control of File Name or Path",
|
|
"cweId": "CWE-73"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"affects": {
|
|
"vendor": {
|
|
"vendor_data": [
|
|
{
|
|
"vendor_name": "Siemens",
|
|
"product": {
|
|
"product_data": [
|
|
{
|
|
"product_name": "Automation License Manager V5",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "*"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "Automation License Manager V6",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "=",
|
|
"version_value": "All versions < V6.0 SP9 Upd4"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"product_name": "TeleControl Server Basic V3",
|
|
"version": {
|
|
"version_data": [
|
|
{
|
|
"version_affected": "<",
|
|
"version_name": "0",
|
|
"version_value": "V3.1.2"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"references": {
|
|
"reference_data": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-476715.pdf"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/html/ssa-476715.html"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-556635.html",
|
|
"refsource": "MISC",
|
|
"name": "https://cert-portal.siemens.com/productcert/html/ssa-556635.html"
|
|
}
|
|
]
|
|
},
|
|
"impact": {
|
|
"cvss": [
|
|
{
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L/E:P/RL:O/RC:C",
|
|
"baseScore": 8.2,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
]
|
|
}
|
|
} |