cvelist/2022/45xxx/CVE-2022-45092.json
2023-01-10 12:00:41 +00:00

74 lines
2.5 KiB
JSON

{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2022-45092",
"ASSIGNER": "productcert@siemens.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
"cweId": "CWE-22"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "SINEC INS",
"version": {
"version_data": [
{
"version_value": "All versions < V1.0 SP2 Update 1",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf",
"refsource": "MISC",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf"
}
]
},
"impact": {
"cvss": [
{
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"baseScore": 9.9,
"baseSeverity": "CRITICAL"
}
]
}
}